General instructions
1. Before bathing for the first time
heat up the heater once to burn off the protective oil solvents. Note
that you need to air the sauna room efficiently afterwards.
2. The heating time is about 45–75 minutes depending
on the size of the room and its ventilation. Throwing water on the heater
increases temperature and humidity. The top of the pillar creates more
heat, while the sides create a gentler steam.
3. The temperature should be set by the temperature control
in the control unit. A recommended temperature for IKI stone pillar is
50–70 degrees.
4. Maintenance Due to large variation in temperature,
the sauna stones disintegrate in use. Pay attention especially to the
gradual settling of the stones. Be sure that the heating elements do not
appear with time. The stones settle most rapidly within two months of
piling. Rearrange the stones at least once a year or even more often if
the sauna is in frequent use. At the same time, remove any pieces of stones
from the bottom of the heater and replace any disintegrated stones with
new ones. By doing this, the heating capability of the heater stays optimal
and the risk of overheating is avoided.
| Model
table |
| |
|
|
|
|
|
| Models |
Size of sauna |
Capacity |
Height of heater |
Diameter of heater |
Max. amount of stones |
| |
|
|
|
|
|
| IKI 3,3 kW |
3-5 m³ |
3,3 kW |
100 cm |
24 cm |
70 kg |
| IKI 5 kW |
4-6 m³ |
5 kW |
128 cm |
24 cm |
90 kg |
| IKI 6 kW |
5-9 m³ |
6 kW |
148 cm |
28 cm |
140 kg |
| Corner IKI 6,6 kW |
5-10m³ |
6,6 kW |
100 cm |
45 cm (radius) |
140 kg |
| IKI 7,5 kW |
7-12m³ |
7,5 kW |
108 cm |
34 cm |
140 kg |
| IKI 10 kW |
10-20m³ |
10 kW |
128 cm |
42 cm |
250 kg |
| IKI 12 kW |
14-24m³ |
12 kW |
148 cm |
34 cm |
200 kg |
| IKI 15 kW |
16-28m³ |
15 kW |
128 cm |
42 cm |
260 kg |
| IKI 18 kW |
18-28 m³ |
18 kW |
148 cm |
42 cm |
300 kg |
| IKI 20 kW |
18-32 m³ |
20 kW |
132 cm |
54 cm |
400 kg |
| IKI 24 kW |
22-36 m³ |
24 kW |
152 cm |
54 cm |
450 kg |
| IKI 30 kW |
26-44 m³ |
30 kW |
132 cm |
74 cm |
600 kg |
| |
|
|
|
|
|
Fuse and connection
cable requirements
| Heater |
Fuse |
Cable |
| 3,3 kW |
|
|
| |
3-phase |
3x10 A |
5x1,5 |
| |
1-phase |
1x16 A |
5x1,5 |
| 5 kW / 6 kW / 6,6 kW |
3x10 A |
5x1,5 |
| 7,5 kW |
3x16 A |
5x2,5 |
| 10 kW |
3x16 A |
5x2,5 |
| 12 kW |
3x20 A |
5x6 |
| 15 kW |
3x25 A |
5x6 |
| 18 kW |
|
|
| |
EC > PC |
3x16 A
3x25A |
5x2,5
5x6 |
| |
PC > heater |
|
5x2,5
5x6 |
| 20 kW |
|
|
| |
EC > PC |
2 x 3x16 A |
2 x 5x2,5 |
| |
PC > heater |
|
2 x 5x2,5 |
| 24/30 kW |
|
|
| |
EC > PC |
2 x 3x25A |
2 x 5x6 |
| |
PC > heater |
|
2 x 5x6 |
EC > PC = Electrical center > Power controller
PC > Heater = Power controller > Heater
IKI Classic and IKI Touch control panels